SHANGFANG Digital Temperature Controller ED106 -45 to 150oC(-45 to 150o F)
Features
Temperature control
Evaporator fan control
Automatic/manual defrost
Defrost by electric heater
Time/temp. seting to end defrost
Re-start delay
Celsius/Fahrenheit degrees
Technical Data
Range of temperature display:-45~150℃ (-45~150℉)
Range of set temperature:-45~45℃ (-40~113℉)
Accuracy:±1℃(±2℉)
Compressor: N.O. 16A/250VAC
Defrost: N.O. 10A/250VAC
Evap. Fan: N.O. 5A/250VAC
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm
Parameters
Parameter | Function | Set range | Default |
E1 | Lower setpoint limit | -45℃/-45℉~Set temp. | -35℃/-31℉ |
E2 | Higher setpoint limit | Set temp.~45℃/113℉ | 45℃/113℉ |
E3 | Temp.Hysteresis | 1~20℃/1.8~36℉ | 4.0℃/7.2℉ |
E4 | Comp.start delay time | 0~10Min | 2Min |
E5 | Offset on room temp. | -20~20.0℃/-36.0~36.0℉ | 0 |
E6 | Offset on evap.temp. | -20~20.0℃/-36.0~36.0℉ | 0 |
F0 | defrost function | 0=Electric heater 1=Hot gas | 0 |
F1 | Max.defrost duration | 1~60Min | 20Min |
F2 | Defrost interval time | 0~24Hr | 6Hr |
F3 | Defrost termination temp. | 0~30℃/32~86℉ | 8℃/46℉ |
F4 | Display during defrost | 0=Normal display | 0 |
F5 | Fan operating function | 0=Parallel with comp. 1 = Continuous running except defrost | 0 |
F6 | Dripping time | 0~30 Min | 2Min |
F7 | Fan delay start mode after defrost | 0=temperature 1= time | 1 |
F8 | Fan delay start time after defrosting. | 0~10Min | 2 Min |
F9 | Fan start temperature after defrosting(evaporator) | -30~30℃ -22~86℉ | 5℃ 41℉ |
C1 | Temperature unit | 0s=℃ 1=℉ | 0 |