Brand: DIXELL
Model: XM679K-5C1C2B
ADVANCED MULTIFUNCTION CONTROLLER FOR N.T. AND L.T. VENTILATED APPLICATIONS WITH AUXILIARY AND ALARM OUTPUTS AND ON/OFF
Generals
Keyboard: 6 push buttons (on CH660, T660H)
Power supply
110, 230Vac
Probe inputs
Thermostat: NTC, Pt1000 - Defrost: NTC, Pt1000 - Display: NTC, Pt1000 - AUX: NTC, Pt1000 - Suction pressure: NTC/Pt1000/4÷20mA/0÷5V - Condesing pressure: NTC/Pt1000
Digital inputs
3 x configurable
Relay outputs
Compressor/Valve: 5A - Defrost: 16A - Fans: 8A - Light: 16A - Alarm: 8A - AUX: 8A
Other
Hot Key / Prog Tool Kit output: present - Serial output: RS485 optional - 4÷20mA/0÷10V output: optional - PWM output: optional - Valve driver output: ON/OFF up to 30W - Remote display output: optional - Buzzer: on keyboard - Real time clock: present - Connection kit: XM-FC21
Power absorption
20VA max
Display
3 digits, red LED, 14,2mm high
Data storing
on the non-volatile memory (EEPROM)
Operating temperature
0÷60 °C
Storage temperature
-25÷60°C
Relative humidity
20÷85% (no condensing)
Measuring and regulation range
NTC probe: -40÷110°C
PTC probe: -50÷150°C
PT1000 probe: -100÷100°CResolution
0.1°C or 1°C
Accuracy (at ambient temperature)
±0.5°C ±1 digit
Features
- Efficient case control thanks to device synchronization (up to 8) by local LAN
- Optimized management of stepper or pulse electronic expansion valves
- Low environmental impact (CO2, R407C and R407F compatible)
- Energy saving through case optimization with auto-adaptive control of superheat
- Energy consumption reduction thanks to ECI fan management via PWM or 0÷10V output
- Anti-sweat heater management through a ”DEW POINT”
- Virtual probe management
- Keyboard with direct access to the main functions
- Internal Real Time Clock
- Hot Key for quick and easy programming
Digital controllers purchased from us should always be diagnosed and installed by a suitably qualified person, if incorrectly installed they will suffer irrepairable damage, for this reason WE CANNOT OFFER ANY WARRANTY on this type of part.